Version | Author | Date | State | Description of Changes |
---|---|---|---|---|
0.1 | Toshan Lash | 02/10/2015 | Working Draft | Initial version. |
0.2 | Toshan Lash | 02/12/2015 | Working Draft | Updated features for further study information. |
0.3 | Toshan Lash | 02/23/2015 | Approved | Changes based on feedback and sample application changes. |
0.4 | Toshan Lash | 04/10/2015 | Add Updated flow diagrams and test diagrams. Added new tag to event to indicate whether a T.4 timeout occurred. | |
...
Sample Call Flows
Below are a couple call flows depicting the use of the new mode 2.
Sample Application Coding
...
Test Scenario(s)
The following testing shall be done at a minimum. The two sample call flows shown above will be tested and it will be confirmed that the results are what is expected. In order to perform the testing, the firmware will need to be modified in several ways. In the firmware function faxSetAdaptiveT4Timer(), faxSendDebug will be called to send to the API debug log the attempt number and the value to be used for setting the T4 timer. In the firmware function faxUpdateAdaptiveT4Timer(), faxSendDebug will be called to send to the API debug log the attempt number, the duration to receive the response or the T4 time out if no response is received and , the current T4 timer value and the T4 timeout indication. In the firmware function faxT4TimerValue(), faxSendDebug will be called to send to the API debug log the new T4 timer value sent to the firmware from the host application.
For the sample call flow number 2, the firmware needs to be modified so that the transmitter ignores the first two CFR responses to the TSI.DCS.TCF sequence. The sample application for this enhancement based on the sample application fax.c will be modified as described above under Sample Application Coding. It will print to the API debug log the attempt number, the duration to receive the response or the T4 time out if no response is received and , the current T4 timer value and the T4 timeout indication. It will also print to the API debug log the new T4 timer value sent to the firmware if it is in fact sent.
...
Filelist will also be run on an SR140 doing 60 channels to 60 channels for 15 minutes using firmware which has not been modified to ignore the first couple CFRs. It will be confirmed that the results are OK.
Results embedded in the API debug log similar to the results shown below in red are expected.
Target Release
SDK 6.7.3
Backward Propagation Release(s)
None
...